A pellet stove runs on a feed screw, an igniter, two fans and a board that tells them what to do. When one part quits, the stove stalls, smokes or shuts itself down. Stanhope tests each part in turn, replaces what failed, and cleans the burn pot, the ash traps and the vent pipe so exhaust leaves the house. The quote is written before parts are ordered.

Feed screw jams cleared and the motor tested
Failed igniters replaced
Exhaust and room fans serviced
Control board and sensor faults found
Burn pot, ash traps and vent pipe cleaned

How a Pellet Stove Fails

Start from the fire and work backward. The fire sits in a small cup called the burn pot, and it only stays healthy if air reaches it from below and ash leaves it. When the holes in the pot clog with clinker, the fire smolders, smokes the glass, and pushes heat back toward the feed. Behind the pot is the feed: an auger, a motorized screw, that pulls pellets from the hopper at a set rate. A worn auger, a jammed pellet or a failed motor starves the fire and the stove shuts down. Around it all are two blowers, one pulling combustion air through and pushing exhaust out the vent, one moving room air across the heat exchanger. If the exhaust blower slows or the vent clogs, the stove senses it and stops, or worse, smoke and sparks find another way out of the box.

That last point is the ember side of a pellet stove. Most pellet stoves vent through a small pipe that leaves the house through a wall, often low on the side of the house, with a cap a short distance from siding, a fence or a planter. Fly ash and the occasional spark leave through that cap. If dry leaves, a woodpile or patio furniture sit right next to it, the cap is a fire source at ground level, which matters in wind season when everything outside is dry. We check the clearances at the termination, clean the vent pipe end to end, and make sure the cap is the right type with its screen in place. Inside, we check the hopper lid switch and the burn back protection, which exist to stop a fire from climbing the feed into the stored pellets.

The Repair Visit

We start with the stove's control panel and any error codes it shows, then open it up. The burn pot comes out and is scraped to clear the air holes. The heat exchanger tubes are brushed, the ash traps emptied, and the exhaust blower housing cleaned, since fly ash builds up on the blower wheel and slows it. We test the igniter, the auger motor and both blowers, and check the door and hopper gaskets, because a pellet stove runs under slight negative pressure and a leaky gasket upsets the air balance. Failed parts get a written price before we replace them. Parts come matched to the stove's make and model, and if parts for an older stove are no longer made, we tell you up front rather than after a second visit has already been booked.

Pellet stoves are less common in Compton and Inglewood than wood fireplaces, but owners who have them often run them hard through the winter, since pellets are an easy fuel to store and a stove heats a room well. A stove used that way needs a full cleaning every season, and a mid-season cleaning if it burns most days. Once the stove is running again, we fire it with you, watch it reach temperature, check that the vent is pulling, and test the carbon monoxide alarm nearest the stove. Landlords with a pellet stove in a rental should have it serviced between tenants, since a new resident may not know the burn pot needs regular emptying. Send the make and model through the contact page and describe what it is doing, and we will bring the likely parts.

Why Choose Stanhope Chimney Solutions?

Roof First

Cap, spark mesh and crown looked at before the flue

Fire Calendar

Caps in late summer, sweeps in early fall, repairs in spring

Written First

Findings and price on paper before any work

Photos of the Roof

Pictures of the cap and crown so you see what we saw

More Ways Stanhope Keeps Embers In

Chimney Sweep

Creosote scraped out of the flue before burn season, so a hot fire cannot light the lining and throw sparks from the top.

See the job

Chimney Inspection

A written look at every place a spark could escape or an ember could enter, from the cap down to the firebox.

See the job

Chimney Repair

Open joints, split tiles and a broken top closed up so the flue carries fire straight out and nowhere else.

See the job

Fireplace Inspection

Firebox, hearth extension, doors and mantel gaps checked for any spot where a popping log could reach something that burns.

See the job

Fireplace Repair

Gapped firebrick, sagging doors and torn spark screens replaced so heat and sparks stay inside the firebox.

See the job

Chimney Level 2 Inspection

Video of each flue joint plus a check where the stack meets framing, booked for a sale, a quake or a fuel switch.

See the job

Chimney Cap Installation

Stainless spark arrestor caps measured to your flue, so burning flakes stay in the chimney when the Santa Anas pick up.

See the job

Chimney Flashing Repair

The metal seal between stack and roof reset, so winter rain stays out of the attic and dry leaves stop piling in the gap.

See the job

Chimney Masonry Repair

Crumbling joints and face-split brick rebuilt so the stack stays tight against sparks and holds together through a shake.

See the job

Chimney Rebuilds

A leaning or quake-split stack taken down and laid up again, with a new flue and a spark arrestor cap on top.

See the job

Fireplace Cleaning

Old ash, half-burnt wood and soot taken out of the firebox and off the doors, with the ash carried out in a metal can.

See the job

Gas Fireplace Cleaning

Lint, spider webs and soot cleared from the burner, ceramic logs and glass, then the flame watched through a full light.

See the job

Gas Fireplace Repair

Pilots that drop out, burners that click without lighting and valves that stick, found with a meter and fixed.

See the job

Fireplace Remodel

New surround, hearth and mantel planned so popping embers land on stone or tile, not on wood floor or carpet.

See the job

Fireplace Inserts

A sealed firebox slid into the old opening, so the fire burns behind glass and no spark reaches the room.

See the job

Wood Stove Repair

Door rope, firebrick, baffles and stovepipe joints renewed so a wood stove burns sealed and sparks stay in the box.

See the job

Gas Logs

A vented gas log set in a working masonry firebox: a flame with no flying sparks and no wood ash to dump.

See the job

Chimney Seismic Retrofit

Bracing, straps or a lighter rebuild above the roof, so a quake does not drop brick or split the flue open.

See the job

Chimney Crown Repair

The concrete slab capping the stack sealed or poured again, so the cap has solid footing and rain stays out of the brick.

See the job

Dryer Vent Cleaning

Packed lint pulled from the duct and the outside hood, so the dryer stops running hot against a wall of fuel.

See the job

Chimney Liner Installation

A stainless liner dropped down a cracked or bare flue, so heat and sparks travel inside steel instead of through gaps.

See the job

Chimney Leak Repair

Water traced from the stain back to the crack, seam or missing cap that lets it in, then stopped at that point.

See the job

Chimney Waterproofing

A breathable repellent soaked into clean brick and mortar, so winter rain beads off instead of soaking the stack.

See the job

Chimney Damper Repair

A rusted, warped or stuck damper freed or replaced, so the flue opens fully for a fire and closes tight after.

See the job

Chimney Chase Cover

A stainless top made to measure for a framed chimney box, with the flue collar and spark cap fitted to it.

See the job
Call (323) 524-3016