Tell Us What the Chimney Is Doing
Wood or gas, the last sweep date and anything odd at the cap. Stanhope calls back to set a visit that fits the season.
What Stanhope covers on this job
An open fireplace pops sparks onto the floor and sends most of its heat up the flue. A sealed insert closes the opening behind glass, keeps sparks off the floor and, on gas units, ends the wood smoke that Rule 445 no-burn alerts restrict. Stanhope checks the firebox and flue first, runs a stainless liner from the insert to the top, connects and leak tests the gas line, and caps the flue with spark mesh.
Why an Insert Changes the Fire Risk
An open masonry fireplace is the least controlled fire in a house. It pulls room air, throws sparks past a screen whenever a log shifts, and sends whatever burns out the top of a flue that may have cracks no one has seen. An insert closes that down. It is a sealed firebox, gas in most of the homes we work on, that slides into the existing opening with glass across the front. The fire burns behind glass, so nothing pops onto the rug. A new liner runs from the insert to the top of the chimney, so exhaust travels through sound pipe instead of the old tile. And with gas, there is nothing glowing up the flue to leave the top as a spark on a windy night. For owners who like the fireplace but worry about wind season, it is often the change that settles the question for good.
Installed prices for a gas insert set into your current firebox run $2,650 to $5,250 here. The range covers the unit itself, the liner from the insert to the top, the gas connection, the surround panel that closes the gap at the fireplace face, and the cap at the top. The higher end is usually larger units, taller chimneys, or a firebox that needs repair before the insert can go in. Wood inserts exist too, and they burn far cleaner than an open fireplace, but wood still makes creosote and sparks and still falls under South Coast AQMD Rule 445 no-burn days, so most owners here choose gas. Before we quote, we look at the firebox, measure the opening, and check the flue to make sure the liner can run its full height without a tight bend or a blocked section.
The Install Visit
An insert install starts with a check of what is already there. The firebox must be sound enough to hold the insert, and the flue must be clear so the liner can drop through. NFPA 211 calls for a Level 2 when the fuel changes, and if the chimney has not had one, we do that first for $370 so the install plan is based on what the camera sees. Then the old damper is removed or fixed open, the liner is dropped from the roof and connected to the insert, the gas line is run with a shutoff valve within reach, and the unit is set and leveled. The top of the liner gets a cap with a screen, sealed to the crown so rain and debris cannot get between the liner and the old tile. A chimney that once had an open top is closed to embers from that point on.
Once the insert is in, we light it with you, check the flame, run a leak test at every fitting, and set up the remote or wall switch. If the remote has a child lock, we show you where it is. The glass on any gas unit gets hot, so we fit the safety barrier screen that most makers now supply, and talk through where small children and pets should keep away. The nearest carbon monoxide alarm gets a test. Owners in Carson and Paramount often book an insert after a buyer's report or a Level 2 flagged a cracked flue, since the liner solves the flue problem and the insert solves the open fireplace at once. Send photos of the fireplace face and opening through the contact page and we will reply with which units fit the opening you have.
Why Choose Stanhope Chimney Solutions?
Roof First
Cap, spark mesh and crown looked at before the flue
Fire Calendar
Caps in late summer, sweeps in early fall, repairs in spring
Written First
Findings and price on paper before any work
Photos of the Roof
Pictures of the cap and crown so you see what we saw
Fireplace Inserts town by town
Each town page explains how the roofs and the weather there shape this job.
CA
Fireplace Inserts in Compton
About three in ten Compton homes went up before 1950, and most of the rest followed in the boom years after the war. On a brick or block stack with gas logs inside, we start at the top: a sound cap keeps sparks in and wind-blown embers out.
View local serviceCA
Fireplace Inserts in Paramount
Most households here rent, and a good share of buildings went up around 1970. Shared walls mean one open flue can send sparks toward a neighbor's roof, so we treat the cap and spark screen as the first thing a landlord's visit covers.
View local serviceCA
Fireplace Inserts in Carson
Owners hold close to three of every four Carson houses, and nearly all of those are detached tracts from after the war. A sixty-year-old stack with a loose cap is an open chute for embers in fall, so fastening is the first thing we test.
View local serviceCA
Fireplace Inserts in Inglewood
Only about a third of homes here are owner-occupied, and many sit in post-war apartment buildings with shared chimney runs. A failed spark screen on one of those stacks puts the whole roof line at risk, so landlords book our cap and sweep checks before the dry season.
View local serviceMore Ways Stanhope Keeps Embers In
Chimney Sweep
Creosote scraped out of the flue before burn season, so a hot fire cannot light the lining and throw sparks from the top.
See the jobChimney Inspection
A written look at every place a spark could escape or an ember could enter, from the cap down to the firebox.
See the jobChimney Repair
Open joints, split tiles and a broken top closed up so the flue carries fire straight out and nowhere else.
See the jobFireplace Inspection
Firebox, hearth extension, doors and mantel gaps checked for any spot where a popping log could reach something that burns.
See the jobFireplace Repair
Gapped firebrick, sagging doors and torn spark screens replaced so heat and sparks stay inside the firebox.
See the jobChimney Level 2 Inspection
Video of each flue joint plus a check where the stack meets framing, booked for a sale, a quake or a fuel switch.
See the jobChimney Cap Installation
Stainless spark arrestor caps measured to your flue, so burning flakes stay in the chimney when the Santa Anas pick up.
See the jobChimney Flashing Repair
The metal seal between stack and roof reset, so winter rain stays out of the attic and dry leaves stop piling in the gap.
See the jobChimney Masonry Repair
Crumbling joints and face-split brick rebuilt so the stack stays tight against sparks and holds together through a shake.
See the jobChimney Rebuilds
A leaning or quake-split stack taken down and laid up again, with a new flue and a spark arrestor cap on top.
See the jobFireplace Cleaning
Old ash, half-burnt wood and soot taken out of the firebox and off the doors, with the ash carried out in a metal can.
See the jobGas Fireplace Cleaning
Lint, spider webs and soot cleared from the burner, ceramic logs and glass, then the flame watched through a full light.
See the jobGas Fireplace Repair
Pilots that drop out, burners that click without lighting and valves that stick, found with a meter and fixed.
See the jobFireplace Remodel
New surround, hearth and mantel planned so popping embers land on stone or tile, not on wood floor or carpet.
See the jobPellet Stove Repair
Pellet stoves that jam, smoke or shut down mid-burn traced to the failed part and put back in service.
See the jobWood Stove Repair
Door rope, firebrick, baffles and stovepipe joints renewed so a wood stove burns sealed and sparks stay in the box.
See the jobGas Logs
A vented gas log set in a working masonry firebox: a flame with no flying sparks and no wood ash to dump.
See the jobChimney Seismic Retrofit
Bracing, straps or a lighter rebuild above the roof, so a quake does not drop brick or split the flue open.
See the jobChimney Crown Repair
The concrete slab capping the stack sealed or poured again, so the cap has solid footing and rain stays out of the brick.
See the jobDryer Vent Cleaning
Packed lint pulled from the duct and the outside hood, so the dryer stops running hot against a wall of fuel.
See the jobChimney Liner Installation
A stainless liner dropped down a cracked or bare flue, so heat and sparks travel inside steel instead of through gaps.
See the jobChimney Leak Repair
Water traced from the stain back to the crack, seam or missing cap that lets it in, then stopped at that point.
See the jobChimney Waterproofing
A breathable repellent soaked into clean brick and mortar, so winter rain beads off instead of soaking the stack.
See the jobChimney Damper Repair
A rusted, warped or stuck damper freed or replaced, so the flue opens fully for a fire and closes tight after.
See the jobChimney Chase Cover
A stainless top made to measure for a framed chimney box, with the flue collar and spark cap fitted to it.
See the job